The acoustic treatment panel CERAFLECTOR® is a 3D controlled-dispersion multidirectional reflection panel.

It is built with the purest enamelled porcelain and its modular design makes it unique in the market.

The angles of reflection of this radial diffusion panel were thoroughly calculated. The depth factor is logarithmically varied and it is, therefore, a three-dimension omnidirectional reflection panel.

The panel CERAFLECTOR® controls primary reflections and fragments them in 64 vertices of incidence using the theoretical numerical sequence ratio of the primitive root as a basis for calculation.

Thus, it produces exceptional results of sound diffusion in all directions and provides spaces with considerable sound perception.

M1 fire resistant. Available in several colours.


Features:

  • Made of porcelain.
  • Average diffusion: 0.67/m2 [>100Hz;<5KHz].
  • 100% recyclable.
  • Fire-resistance: M1.
  • Package: 2 units
  • Installation: accessories included.

View this product's photo.
3D Acoustic Diffusion Scattering Simulation Video.
View this product's interactive 3D Animation and it's specification.
Technnical Specifications.
 
Weight
Height
Width
Depth
24 Kg
120 cm
60 cm
12.9 cm
 
Weight
Height
Width
Depth
12 Kg
60 cm
60 cm
12.9 cm
 
 
     
 
 
.004
.08
.36
0.37
0.42
0.46
0.48
0.49
0.57
0.62
0.63
0.66
0.72
0.78
0.81
0.80
0.83
0.83
0.85
0.89
0.87
0.81
0.76
0.70
 
0.67
 
.01
.06
.07
0.18
0.27
0.38
0.31
0.14
0.12
0.16
0.13
0.14
0.17
0.21
0.34
0.46
0.41
0.37
0.34
0.36
0.37
0.33
0.27
0.23
 
0.22
 
 
 
αs
 
 
αs
 
 
1.4
1.2
1.0
0.8
0.6
0.4
0.2
 
 
HZ
50
63
80
100
125
160
200
250
315
400
500
630
800
1K
1.25 K
1.6K
2 K
2.5 K
3.15 K
4 K
5 K
6.3 K
8 K
10 K
 
NRC
 
 
   
FREQUENCY (HZ)
 
These values were obtained by mathematical calculations and tests carried out in our laboratory
  Values in accordance with the Standards: EN20654, ASTM C423 and EN 11654
 
Values [<100Hz and > 5K] are Non Standard Values